Contents: Removal ↡ Installation ↡
Removal
1. Remove the electrohydraulic unit and disconnect the wiring from it.
2. Remove clamps 2 and 4 (see figure 6.61a,b).
Figure 6.61a. Gear shift solenoid valves:
1. Bolt,
2. Fixator,
3. Seal,
Y72, Y74. Pressure regulator,
Y75. Gear shift solenoid valve.
Figure 6.616. Gear shift solenoid valves:
1. Bolt,
2, 4. Retainer,
3. Seal,
Y71, Y73. Pressure regulator,
Y76. Gear shift solenoid valve.
3. Remove solenoid valves Y75 and Y76.
4. Remove pressure regulators Y71-Y74.
5. Press out the seals 3.
Installation
6. Installation is carried out in the reverse order of removal. Replace seals 3.
(Read more on the website: mercedesman)