Removing
1. Remove the electro-hydraulic unit and disconnect the wiring from it.
2. Remove clips 2 and 4 (see fig.6.61a,b).
Pic. 6.61a. Shift Solenoid Valves:
1. Bolt,
2. Retainer,
3. Oil seal,
Y72, Y74. pressure regulator,
Y75. Solenoid shift valve.
Pic. 6.616. Shift Solenoid Valves:
1. Bolt,
2, 4. Retainer,
3. Oil seal,
Y71, Y73. pressure regulator,
Y76. Solenoid shift valve.
3. Remove solenoid valves Y75 and Y76.
4. Remove pressure regulators Y71-Y74.
5. Press out seals 3.
Installation
6. Installation is made in an order, the return to removal. Replace seals 3.