Contents: Removal ↡ Installation ↡
Removal
1. Disconnect the wiring connector 4 from the transmission protection valve Y7 (see figure 4.60).
Figure 4.60. Transmission protection valve:
1, 2, 3. Branch pipes,
4. Wiring connector,
5. Spring,
Y7. Transmission protection valve.
2. Remove the clamps and disconnect the tubes from ports 1, 2 and 3 of the transmission protection valve Y7.
3. Press the spring and after a while remove the transmission protection valve Y7 from the mounting bracket.
Installation
4. Installation is carried out in the reverse order of removal.