Contents: Removal ↡ Installation ↡
Removal
1. Loosen clamps 1 securing air flow sensor 2 to filter housing 3 (see figure 3.7).
Figure 3.7. Air filter:
1. Clamp,
2. Air flow sensor,
3. Air filter,
4. Connector,
5. Air intake pipe,
6. Elastic band.
2. Disconnect connector 4 from air flow sensor 2.
3. Remove the air intake pipe 5.
4. Disconnect rubber band 6 from filter 3.
5. Remove filter 5.
Installation
6. Installation is carried out in the reverse order of removal. Make sure the attached filter is not damaged.