Additional heating can be switched on when the vehicle engine is not running or running.
Switching on the heater:
The heater is activated by a clock located above the interior rear-view mirror.
Attention! Additional heating must be switched on at least once a month for approx. for 10 minutes.
If the fuel reserve is less than 15 liters, the auxiliary heating switches off automatically.
Fan and air conditioning when auxiliary heating is on
In preheating mode with auxiliary heating on, the fan automatically switches to stage 1. Any fan stage can be selected while driving. In vehicles without air conditioning, before switching on the heater or after entering the preselection time, the temperature controller must be set to the maximum heating output (red range). In vehicles with air conditioning, setting the temperature controller to the maximum heating output is not required.
Watch service
1 Symbol — current time is displayed.
2 Symbol — preselection time is activated.
3 button - activation of the resettlement time, setting hours and minutes.
4 Actual time or preselection time.
5 The symbol is a control LED.
6 button - turn on the heater, set hours and minutes.
Attention! If the power supply is restored after an interruption, all symbols and numbers flash on the display. In this case, the clock must be reset.
The heater can only be switched on after setting the time on the clock. The watch can memorize the preselection time. The preselection time can be selected within 24 hours. The heating time is 60 minutes. The clock is illuminated when the heater is switched on.
Switching on additional heating
Press the button - the heating time is 60 minutes. Indication: remaining time and symbol . Turn off the heater: press the button. Run-out is made within 3 minutes. Indication: current time and symbol . Preselection time activation: press the button. Indication: preselection time and symbol are displayed before the heater is started. Turn on the heater: press the button; display: the current time and the symbol .
Time setting
Simultaneously press the button and the button.
The clock is flashing.
Clock setting: press the button.
Setting minutes: press the button.
The minutes are flashing. Press the button.
After completing the installation, press the button or wait 10 seconds until the current time and the symbol are displayed.
Call/set the preselection time.
Press the button, then simultaneously press the button and the button, the clock will flash.
Clock setting: press the button.
Setting minutes: press the button. The minutes are flashing - press the button.
Memorize preselection time:
Please wait 10 seconds after installation. The current time and symbol are displayed.
Preselection time activation: press the button. The preselection time and are displayed. The heater is switched on at the indicated preselection time.
Operation of auxiliary heating
When switched on, the symbol in the hours lights up. After approximately 20-50 seconds, the heater starts to operate at full heat flow.
Heating mode
Depending on the heat demand, different operating states are set.
Heat dissipation 5,000 W or more: Heater at ''Full power' stage".
Heat dissipation between 1,250 W and 5,000 W - heater switches between stages "Full power" And "¼ power".
Less than 1250 W heat dissipation: the heater switches between stages "Off" And "Full power".
Switching off auxiliary heating
When switched off, the symbol in the hours goes out. An escape is made. The blower fan and water pump run for 120 seconds and then turn off automatically.
Safety devices
In the event of faults leading to overheating of the heater, the heater switches off automatically for safety reasons. The control unit contains a diagnostic system that recognizes faults, stores them in memory and displays them. In the event of a malfunction, contact an authorized workshop as soon as possible in order to eliminate it.