Contents: Removal ↡ Installation ↡
Removal
1. Disconnect connector 3 from vacuum pressure transducer Y44 (see figure 4.48).
Figure 4.48. Vacuum converter of the exhaust gas recirculation system:
1. Exhaust gas recirculation valve,
2. Throttle valve,
3. Wiring connector,
4. Atmospheric pressure tube connection,
5. Inlet pipe nipple,
6. Outlet pipe branch,
Y44. Vacuum converter.
2. Disconnect the tubes from ports 4, 5 and 6 on the Y44 converter.
3. Remove the Y44 converter from the bracket.
Installation
4. Installation is carried out in the reverse order of removal.