Removing
1. Disconnect the compressed air supply pipe from mixing chamber 1 (see fig.5.56).
Pic. 5.56. CDI coolant temperature sensor:
1. Mixing chamber,
2. Wiring connector,
3. Retaining ring,
B60. Coolant temperature sensor.
2. Disconnect the wiring connector 2 coolant temperature sensor B60.
3. Remove the radiator cap to reduce system pressure.
4. Remove the coolant temperature sensor B60. Using a screwdriver, press out retaining ring 3.
Installation