Removing
1. Drain the coolant.
2. Remove the mass air flow measurement sensor.
3. Loosen the bolts 1 fastening the pulley 2 (see fig.3.35).
Pic. 3.35. Coolant pump:
1, 5. Bolt,
2. Coolant pump pulley,
3. Coolant pump,
4. Drive belt for alternator and coolant pump,
6. Cylinder block,
7. O-ring.
4. Remove the drive belt of the generator and the cooling system pump 4.
5. Turn off bolts 1 fastenings of a pulley 2.
6. Remove pulley 2 from pump 3.
7. Unscrew the bolts 5 fastening the pump 3.
8. Remove the cooling system pump 3.
Installation
9. Installation is made in an order, the return to removal. Replace O-ring 7. Wipe sealing surfaces.