Mechanical window lifter
1. Remove the cover (four screws), remove the retaining ring and disconnect the intermediate lever and guide plate.
2. Lift the glass and support it with a wooden block.
3. Loosen the mounting bolts and remove the window regulator through the opening.
4. Installation is carried out in the reverse order of removal.
Electric window lift
1. Push out the rocker switch and disconnect the wiring connector block. Also disconnect the motor wiring from the terminal block, noting the position of the wires.
2. Loosen the mounting screws and remove both covers.
3. Unscrew the fastener and remove the cover.
4. Remove the retaining ring and disconnect the intermediate lever from the guide plate.
5. Loosen the window regulator mounting nuts, lower the glass and remove the window regulator from the top.
6. Installation is carried out in the reverse order of removal.