Details of the installation of the fuel distribution line
1 - Cover of the power unit with built-in air cleaner; 2 - Service valve; 3 - Retainer; 4 - Plastic cover; 5 - Fuel line; 6 - Fuel supply line; 7 - Bolts; Y62 - Fuel injector
1. Remove the cover of the power unit with built-in air cleaner (1) (see Section Removal and installation of components of an inlet air path).
2. Loosen the latch (3).
3. Remove the plastic cover (4).
4. Relieve pressure in the fuel system through the service valve - prepare to collect the displaced fuel.
5. Loosen the fuel line (6).
6. Turn out fixing bolts (7) and remove the fuel rail (5) complete with injectors (Y62) from the intake pipe.
7. Installation is carried out in the reverse order.
Injectors
Details of installation of fuel injectors
16/7 - Anti-rotation lock
17 - Fuel line
Y62 - Fuel injectors
Arrow - Rectangular nozzle
1. Remove the fuel distribution line (17).
2. Remove the injectors (Y62).
3. Installation is made upside-down, - in case of need replace sealing rings. O-rings should be lubricated with oil before installation. Make sure that the anti-rotation locks (16/7) snapped onto rectangular nozzles (arrow).